Wednesday, August 20, 2003 - 3 Posts
I have a problem with piping of 12.5% chlorine. It seems like the piping but especially fittings
it is still a safety problem and the smell is bad. We are using PVC pipe. Long time ago (before me
used HDPE Piping with Fibre Glass Lining from outside (throughout the piping). Minor Leakage
|
|
Friday, October 23, 2009 - 4 Posts
I would like your support for the following problem:
I tried to decide the plastic piping material
all piping in the container and most of time is under the water , b) I would think it non-pressure
very small very quickly.
For larger, underground PVC pipes, gasketed joints are used.
However
|
|
Thursday, March 19, 2009 - 5 Posts by 4 People
And HDPE pipe. What are your experiences with it as I don't get to physically weld as much as I used
i've posted some photos about hdpe and butt fusion when i do trenchless sewer pipe bursting.
do
the pipe.
up here all of our sewer and water mains and services are HDPE.
pretty good stuff.
the last
|
|
Monday, April 13, 2009 - 4 Posts
As if a joint fails or pipe bursts, the GPM of some of my systems rises above 60 GPM and this would
handling temperatures can drop to around 30 degrees F. HDPE performs well under these temperatures
reason that you have described with the problems of the fusion pipe work.we do primarily closed loop
|
|
Wednesday, October 07, 2009 - 12 Posts by 6 People
pipes under the slab in. Room will have spray foam with pella windows and doors (hopefully a very
the pipe around. I would certainly want water tight joints, and an impervious skin inside and outside
here under slabs are an insulated fiberglass pipe similar to the links above... SpunStrand
|
|
Friday, December 26, 2008 - 11 Posts by 5 People
Are certified under IS4885., HDPE pipes are certified under IS4984....
DevarajanThanks for clearing
/pvctech.htm
"Keep Your Powder (& Resin!)Dry!!"Sir,
if i have to get my SWR pipes certified
Hi,
I am desperately looking for a manufacturer of solvent cement with ISI certification in India. Please share the information...
|
|
Tuesday, July 07, 2009 - 8 Posts
Are the basics:
72'' diameter pipe to be installed deep in high plasticity clay soils on a slope
soil. Welded HDPE might be better than concrete pipe. HDPE could also be joined up top
the funds. The problem with the heavy material is the compaction under the arches of the pipe
|
|
Sunday, September 21, 2008 - 25 Posts by 9 People
Removable later:
05.JPG
McMaster Carr flexible PVC brush:
P9190167.jpg
06.JPG
12mm thick HDPE
stiffener for inside the foot. Self-tapping screws will pass through the sheet into the HDPE
07.JPG
08.JPG
P9200172.JPG
P9200173.JPG
Experimenting with some wire in the joint to tighten the grip and twist
|
|
Monday, January 19, 2009 - 5 Posts
We directional drilled a 3" HDPE dr17 sewer forcemain, 200 metres in sandy conditions. Driller
the forcemain came back it was oblong shaped. it doesnt look like the pipe failed but definately stressed
to speak) of the "oblong" shape you observed. However, I have seen sort of oblong-shaped hdpe pipe
|
|
Thursday, October 22, 2009 - 9 Posts by 4 People
Sticked
rear driveshaft upgraded to 1350 ujoints and schedule 40 pipe
HDPE plastic belly pan
42
gears and both diffs welded
front and rear are 35 spline chromoly
spicer joints and warn drive flanges
This is my personal buggy. It's been everything I had hoped it would be, but I'm ready for something different. Looking for...
|
)